Single Phase Energy HubInverter with Prism Technology for North America
SE3000H-US / SE3800H-US / SE6000H-US / SE7600H-US(1)
Optimized battery storage with HD-Wave technology
Record-breaking 99% weighted efficiency with 200% DC oversizing
Small, lightweight, and easy to install
Modular design, future ready with optional upgrades to:
DC-coupled storage for full or partial home backup Built-in consumption monitoring
Direct connection to the SolarEdge smart EV charger
Multi-inverter, scalable storage solution
Integrated arc fault protection and rapid shutdown for NEC 2014, NEC 2017 and NEC 2020, per article 690.11 and 690.12
Embedded revenue grade production data, ANSI C12.20 Class 0.5
solaredge.com
12-25
YEAR WARRANTY
HOME BACKUP
Single Phase Energy Hub Inverter
with Prism Technology for North America
SE3000H-US / SE3800H-US / SE6000H-US / SE7600H-US(1)
SE3000H-US
SE3800H-US
SE6000H-US
SE7600H-US
UNITS
OUTPUT - AC ON GRID
Rated AC Power
3000
3800
6000
7600
W
Maximum AC Power Output
3000
3800
6000
7600
W
AC Output Voltage Range
211-264
Vac
AC Frequency Range (min - nom - max)
59.3 - 60 - 60.5(2)
Hz
Maximum Continuous Output Current
12.5
16
25
32
A
GFDI Threshold
1
A
Total Harmonic Distortion (THD)
<3
%
Power Factor
1, adjustable -0.85 to 0.85
Utility Monitoring, Islanding Protection, Country Configurable Thresholds
Yes
Charge Battery from AC (if allowed)
Yes
Typical Nighttime Power Consumption
<2.5
W
OUTPUT - AC BACKUP(3)
Rated AC Power in Backup Operation(4)
AC L-L Output Voltage Range in Backup
AC L-N Output Voltage Range in Backup
AC Frequency Range in Backup (min - nom - max)
Maximum Continuous Output Current in Backup Operation
3000 3800 7600*
12.5 16 32*
211 - 264
105 - 132 55 - 60 - 65
6000
25
7600 W
Vac Vac Hz
32 A
GFDI 1A THD <5%
OUTPUT - SMART EV CHARGER AC
Rated AC Power
AC Output Voltage Range
AC Frequency Range (min - nom - max)
Maximum Continuous Output Current @240V (grid, PV and battery)
9600 W 211 - 264 Vac 59.3 - 60 - 60.5 Hz 40 Aac
INPUT - DC (PV AND BATTERY)
Transformer-less, Ungrounded
Yes
Max Input Voltage
480
Vdc
Nom DC Input Voltage
380
Vdc
Reverse-Polarity Protection
Yes
Ground-Fault Isolation Detection
600k? Sensitivity
INPUT - DC (PV)
Maximum DC Power
6000
7600
12000
15200
W
15200*
Maximum Input Current(5)
8.5
10.5
16.5
20
Adc
20*
Max. Input Short Circuit Current
45
Adc
Maximum Inverter Efficiency
99.2
%
CEC Weighted Efficiency
99
%
2-pole Disconnection
Yes
INPUT - DC (BATTERY)
Supported Battery Types
Number of Batteries per Inverter Maximum Battery Capacity per Inverter Continuous Power Per Inverter(8)
Peak Power(8)
Max Input Current @240V
2-pole Disconnection
LG Chem RESU 10H & RESU16H Prime(6) 1 or 2(7)
19.6 kWh 5000 W 7000 W
18 Adc Yes
Single Phase Energy Hub Inverter
with Prism Technology for North America
SE3000H-US / SE3800H-US / SE6000H-US / SE7600H-US(1)
Built - in(9)
With Backup Interface (purchased separately) for service up to 200A; Up to 3 inverters, 15kW backup power, and 60kWh backup capacity
Direct connection to Smart EV charger
RS485, Ethernet, Wi-Fi (optional), Cellular(10)
Built - in(9)
Yes
With the SetApp mobile application using built-in Wi-Fi Access Point for local connection Yes, according to NEC 2014, NEC 2017 and NEC 2020 690.12
UL1741, UL1741 SA, UL1741 PCS, UL1699B, UL1998, UL9540, CSA 22.2 IEEE1547, Rule 21, Rule 14H
FCC part 15 class B
SMART ENERGY CAPABILITIES
Consumption Metering
SE3000H-US
SE3800H-US
SE6000H-US
SE7600H-US
UNITS
Backup & Battery Storage
EV Charging
ADDITIONAL FEATURES
Supported Communication Interfaces
Revenue Grade Metering, ANSI C12.20
Integrated AC, DC and Communication Connection Unit
Inverter Commissioning
DC Voltage Rapid Shutdown (PV and Battery)
STANDARD COMPLIANCE
Safety
Grid Connection Standards
Emissions
INSTALLATION SPECIFICATIONS
AC Output Conduit Size / AWG Range
EV AC Output Conduit Size / AWG Range
DC Input (PV) Conduit Size / AWG Range
DC Input (Battery) Conduit Size / AWG Range
Dimensions with Connection Unit (H x W x D)
Weight with Connection Unit
Noise
Cooling
Operating Temperature Range
Protection Rating
3/4'' maximum / 14-8 AWG
3/4'' maximum / 14-8 AWG
3/4'' maximum / 14-8 AWG
3/4'' maximum / 14-8 AWG
26 / 11.8 < 25
3/4'' maximum / 14-8 AWG 1'' maximum / 14-4 AWG* 3/4'' maximum / 14-8 AWG 1'' maximum / 14-64AWG* 3/4'' maximum / 14-8 AWG 1'' maximum / 14-6 AWG* 3/4'' maximum / 14-8 AWG 1'' maximum / 14-6 AWG*
1'' maximum / 14-4 AWG
1'' maximum / 14-4 AWG
1'' maximum / 14-6 AWG
1'' maximum / 14-6 AWG
17.7 x 14.6 x 6.8 / 450 x 370 x 174
26 / 11.8 30.2 / 13.7* < 25
< 50*
Natural Convection -40 to +140 / -40 to +60(11) NEMA 4
30.2 / 13.7
< 50
in / mm lb / kg
dBA ?F / ?C
* Supported with PN SE3800H-USMxxxxxx
(1) These specifications apply to inverters with part numbers SExxxxH-USS3Bxxxx, SE3800H-USMxxBCxx or SE7600H-USSSHxxxx and connection unit model number DCD-1PH-US-PxH-F-x (2) For other regional settings please contact SolarEdge support
(3) Not designed for standalone applications and requires AC for commissioning
(4) Rated AC power in Backup Operation are valid for installations with multiple inverters. For a single backup inverter operation, rated AC power in Backup is 90% of the value stated
(5) A higher current source may be used; the inverter will limit its input current to the values stated
(6) Requires supporting inverter FW for RESU16H Prime battery
(7) When connecting two LG Chem RESU10H batteries, each battery must have a different part number. LG Chem RESU16H Prime is supported with a single battery only
(8) Discharge power is limited up to inverter rated AC power
(9) For consumption metering current transformers should be ordered separately: SEACT0750-200NA-20 or SEACT0750-400NA-20. 20 units per box.
Revenue grade metering is only for production metering (10) For all cellular plans customer must verify that:
· Customer is responsible for verifying that the site location has adequate mobile coverage by the third party service provider prior to any installation by accessing https://www.solaredge.com/products/ communication/cellular-communication-options#/
· SolarEdge shall not be responsible or liable for unavailability or discontinuance of network coverage in a specific area or region, any network downtime, or permanent service shutdown (11) Full power up to at least 50°C / 122°F; for power de-rating information refer to: https://www.solaredge.com/sites/default/files/se-temperature-derating-note-na.pdf
Single Phase Energy Hub Inverter
with Prism Technology
for North America
SE3000H-US / SE3800H-US / SE6000H-US / SE7600H-US(1)
Connecting CTs to the Revenue Grade and Consumption Meter
Single Phase Energy Hub Inverter with Prism Technology
Grid
© SolarEdge Technologies, Inc. All rights reserved. SOLAREDGE, the SolarEdge logo, OPTIMIZED BY SOLAREDGE are trademarks or registered trademarks of SolarEdge Technologies, Inc. All other trademarks mentioned herein are trademarks of their respective owners. Date: 03/2021/V02/ENG NAM. Subject to change without notice.